When Enabling EN Grade true, these settings are forced onto panel for higher security:
- Entry Procedure (EU) - follows entry procedures and alarm transmission delays specified by EN
50131
- Disables the “Auto Bypass” setting so that the Panel will protest arming when sensor and panel
trouble conditions are present (i.e. Open, Tamper, Low Battery, etc)
- Trouble condition alerts can not be acknowledged until the condition is resolved
- Trouble beeps are expanded to include fault indications required by EN 50131
- “Screen Lock” setting is enabled automatically. Screen will lock 30 seconds after Disarming
- A new icon called “EU Events” is added to the “Settings" page which records mandatory history
events specified by EN 50131.
- “Loss of Supervisory Signals for PowerG Non-Emergency Sensors” is set to 2 hours by default.
- “LED Indicator” setting is Disabled automatically.
- “Partitions” setting is not available.
- “Dealer or Installer Access Requires User Permission” setting is Enabled automatically.