Test Restore Report Code

1 min. readlast update: 10.17.2023

1) Enter Installer Code on the panel while disarmed (Default 4112) + 800

2) You Will now see 20 INSTALLER CODE if that was the correct installer code.

3) Press *76

Report is sent when the test mode is exited. A restore code entered here will cause a

restore message to be sent when Test mode is exited.

Note: The LynxSIA Plus validates the data entered in this field. If the selection is not valid

the control will emit a single long beep indicating that the selection has been

rejected. The control replaces the selection with the default value, which is

displayed on the keypad, and advances to the next field.

4) Press *99 After the screen updates to the next field to exit programming

Note: GeoArm can change the installer code upon activation

Follow Install manual for more information: 

https://turbifycdn.com/ty/cdn/yhst-51756635596032/l3000-honeywell-lynx-plus-wireless-control-panel-installation-and-setup-guide.pdf