Option Selection - Enable Remote Internet Services - Enabling App Control In Programming Vista 15p-20p

1 min. readlast update: 10.17.2023

1) enter Installer Code into a PROGRAMMING KEYPAD ONLY (Default 4112) + 800

2) enter *91

3) Enter Desired Field (Input guide will be posted below this)

Inputs:

Note: If you are using remote internet services, input 8 + 2 here.

0 = None

4 = AAV

8 = Exit Delay Restart/Reset UL: must be disabled #+12 = AAV and Exit Delay Restart/Reset

SIA Guidelines: Exit Delay should be enabled. 

4) enter *99 to exit programming

Note:

The Vista 15P does not have partitions, any fields dealing with partitions will not be available on the Vista 15P

Programming Manual For More Information

GeoArm can assist in changing the installer code upon activation.  

Was this article helpful?