Misc Fault Delay Time Vista 15p-20p

1 min. readlast update: 10.17.2023

used with Configurable Zone Types “digit 6”

1) enter Installer Code into a PROGRAMMING KEYPAD ONLY (Default 4112) + 800

2) enter *87

3) Enter Desired Field (Input guide will be posted below this)

Inputs:

0 = 15 seconds

1 = 30 seconds

2 = 45 seconds

3 = 60 seconds

4 = 90 seconds

5 = 2 minutes 

6 = 2-1/2 min

7 = 3 min

8 = 4 min

9 = 5 min 

#+10 = 6 min 

#+11 = 7 min 

#+12 = 8 min

#+13 = 10 min

#+14 = 12 min

#+15 = 15 min

4) enter *99 to exit programming

Note:

The Vista 15P does not have partitions, any fields dealing with partitions will not be available on the Vista 15P

Programming Manual For More Information

GeoArm can assist in changing the installer code upon activation.  