1) enter Installer Code into a PROGRAMMING KEYPAD ONLY (Default 4112) + 800
NOTE: This is a command to the panel that will reset your panel to default settings, please only continue if you understand that this will reset the panel
2) enter *96 or *97
*96 - Initializes download ID and subscriber account number
*97 - Sets all data fields to original factory default values.
4) enter *99 to exit programming if you haven't been kicked out of programming
Note:
The Vista 15P does not have partitions, any fields dealing with partitions will not be available on the Vista 15P
Programming Manual For More Information