1) enter Installer Code into a PROGRAMMING KEYPAD ONLY (Default 4112) + 800
2) enter *197
3) Enter Desired Field (Input guide will be posted below this)
Inputs:
0 = no display
1-5 = seconds between display refresh
NOTE: If enabled and using only 2-digit fixed-word keypads (e.g., 6150RF), do not set exit delay time greater than 96 seconds. See Inst. Instr. for explanation. TOUCH SCREEN DEVICE NOTE: If using more than one touch screen device (e.g., 6270, Symphony) with the system, leave field *197 Exit Time Display Interval set to the default value “0.” The 6270 automatically displays remaining exit time in one-second increments.
4) enter *99 to exit programming
Note:
The Vista 15P does not have partitions, any fields dealing with partitions will not be available on the Vista 15P
Programming Manual For More Information
GeoArm can assist in changing the installer code upon activation.