Exit Error Report Code

1 min. readlast update: 10.17.2023

1) Enter Installer Code on the panel while disarmed (Default 4112) + 800

2) You Will now see 20 INSTALLER CODE if that was the correct installer code.

3) Press *59 to begin editing exit error report code

If 3+1 or 4+1 format is used, only the digit entered in this field will be sent. This message

will go to the Primary Phone Number. No restore message will be sent under any of

these conditions,.

If “0” is entered in this field, no special message will be sent, only the regular alarm and

alarm restore code for the zone

4) Press *99 After the screen updates to the next field to exit programming

Note: GeoArm can change the installer code upon activation

Follow Install manual for more information: 

https://turbifycdn.com/ty/cdn/yhst-51756635596032/l3000-honeywell-lynx-plus-wireless-control-panel-installation-and-setup-guide.pdf