(This field applies only to the LynxSIA Plus control)
1) Enter Installer Code on the panel while disarmed (Default 4112) + 800
2) You Will now see 20 INSTALLER CODE if that was the correct installer code.
3) Press *57 to begin changing false alarm options
Enter either of the follow options to change select settings
Cancel Alarm Display | Auto Stay Arming | Exit Time Restart/Reset
0 = Disabled Disabled Disabled
1 = Disabled Disabled Enabled
2 = Disabled Enabled Disabled
3 = Disabled Enabled Enabled
4 = Enabled Disabled Disabled
5 = Enabled Disabled Enabled
6 = Enabled Enabled Disabled
7 = Enabled Enabled Enabled
4) Press *99 After the screen updates to the next field to exit programming
Note: GeoArm can change the installer code upon activation
Follow Install manual for more information: