Disable Auto Stay Arming / Enable Auto Stay Arming

3 min. readlast update: 10.17.2023

(This field applies only to the LynxSIA Plus control)

1) Enter Installer Code on the panel while disarmed (Default 4112) + 800

2) You Will now see 20 INSTALLER CODE if that was the correct installer code.

3) Press *57 to begin changing false alarm options

Enter either of the follow options to change select settings

       Cancel Alarm Display | Auto Stay Arming | Exit Time Restart/Reset

0 = Disabled Disabled Disabled

1 = Disabled Disabled Enabled

2 = Disabled Enabled Disabled

3 = Disabled Enabled Enabled

4 = Enabled Disabled Disabled

5 = Enabled Disabled Enabled

6 = Enabled Enabled Disabled

7 = Enabled Enabled Enabled 

4) Press *99 After the screen updates to the next field to exit programming

Note: GeoArm can change the installer code upon activation

Follow Install manual for more information: 

https://turbifycdn.com/ty/cdn/yhst-51756635596032/l3000-honeywell-lynx-plus-wireless-control-panel-installation-and-setup-guide.pdf