Cross Zone Timer - Zone Verification Timer Vista 15p-20p

1 min. readlast update: 10.17.2023

using *81 Menu mode (ZONE LIST MENU MODE)

1) enter Installer Code into a PROGRAMMING KEYPAD ONLY (Default 4112) + 800

2) enter *85

3) Enter Desired Field (Input guide will be posted below this)

Inputs:

0 = 15 seconds

1 = 30 seconds

2 = 45 seconds

3 = 60 seconds

4 = 90 seconds

5 = 2 minutes 

6 = 2-1/2 min

7 = 3 min

8 = 4 min

9 = 5 min 

#+10 = 6 min 

#+11 = 7 min 

#+12 = 8 min

#+13 = 10 min

#+14 = 12 min

#+15 = 15 min

4) enter *99 to exit programming

Note:

The Vista 15P does not have partitions, any fields dealing with partitions will not be available on the Vista 15P

Programming Manual For More Information:

https://turbifycdn.com/ty/cdn/yhst-51756635596032/honeywell-vista-20p-control-panel-programming-guide.pdf

GeoArm can assist in changing the installer code upon activation.