using *81 Menu mode (ZONE LIST MENU MODE)
1) enter Installer Code into a PROGRAMMING KEYPAD ONLY (Default 4112) + 800
2) enter *85
3) Enter Desired Field (Input guide will be posted below this)
Inputs:
0 = 15 seconds
1 = 30 seconds
2 = 45 seconds
3 = 60 seconds
4 = 90 seconds
5 = 2 minutes
6 = 2-1/2 min
7 = 3 min
8 = 4 min
9 = 5 min
#+10 = 6 min
#+11 = 7 min
#+12 = 8 min
#+13 = 10 min
#+14 = 12 min
#+15 = 15 min
4) enter *99 to exit programming
Note:
The Vista 15P does not have partitions, any fields dealing with partitions will not be available on the Vista 15P
Programming Manual For More Information:
https://turbifycdn.com/ty/cdn/yhst-51756635596032/honeywell-vista-20p-control-panel-programming-guide.pdf
GeoArm can assist in changing the installer code upon activation.