Cancel Verify Keypad Display Vista 15p-20p

1 min. readlast update: 10.17.2023

1) enter Installer Code into a PROGRAMMING KEYPAD ONLY (Default 4112) + 800

2) enter *86

3) Enter Desired Field (Input guide will be posted below this)

Inputs:

0 = no “alarm canceled” display

 1 = display “Alarm Canceled” when system is disarmed after an alarm has occurred. (To clear the “ALARM CANCELED” display, the user must enter the security code + OFF again.) 

4) enter *99 to exit programming

Note:

The Vista 15P does not have partitions, any fields dealing with partitions will not be available on the Vista 15P

Programming Manual For More Information:

https://turbifycdn.com/ty/cdn/yhst-51756635596032/honeywell-vista-20p-control-panel-programming-guide.pdf

GeoArm can assist in changing the installer code upon activation.