Audible Exit Warning-Quick Exit

1 min. readlast update: 10.17.2023

1) Enter Installer Code on the panel while disarmed (Default 4112) + 800

2) You Will now see 20 INSTALLER CODE if that was the correct installer code.

3) Press *37

Quick Exit: If enabled, the user can restart the exit delay time after arming in STAY

mode by entering the User Code and pressing the STAY key, or by pressing the STAY

key if Quick Arm is enabled. This avoids having the user disarm then re-arm the

system after allowing someone to enter or exit

0 = no exit warning sound

1 = provide exit warning sound when armed AWAY

4) Press *99 After the screen updates to the next field to exit programming

Note: GeoArm can change the installer code upon activation